Last year, while updating our wood door specifications, I became a little confused while trying to figure out the finish systems specified in AWI/AWS and WDMA standards. In the past I had specified wood doors using AWI standards, but after investigating the relevant standards, I changed our wood door specifications to use the WDMA standards because they are more specific to wood doors. However, because some literature refers to AWI and some to AWS standards, and some refers to current standards while others refer to old ones, I created a conversion table so I don’t have to go back to the standards whenever we get shop drawings.
Standards of the Architectural Woodwork Institute (AWI) and the Wood Door Manufacturer’s Association (WDMA) have been similar for a long time, and in most cases, a door that meets Premium Grade standards for one will meet them for the other. Perhaps the most important exception is face veneer grades, but I'm going to limit this discussion to finish standards.
The focus of this blog is construction-related topics. The purpose is discussion, so please feel free to comment! See Specific thoughts for thoughts from the daily life of a specifier.
30 May 2010
02 May 2010
Missing Standards
Although there may be a few products that require little thought in specifying, most require some minimum amount of research, comparison of similar products, and determination of the right combination of characteristics best suited to a project.
Even then, the process can be straightforward and fairly simple, provided the type of product is common, governed by widely accepted standards for materials and performance, well-described in product data, and supported by reputable manufacturers and representatives. Hollow metal doors and frames are a good example. Most manufacturers produce them according to one or both of two sets of common industry standards, published by the Steel Door Institute (SDI) and the National Association of Architectural Metal Manufacturers (NAAMM). Unfortunately, not all types of building products can be specified by use of similar standards.
Before you start that e-mail telling me how difficult it is to specify hollow metal doors,
Even then, the process can be straightforward and fairly simple, provided the type of product is common, governed by widely accepted standards for materials and performance, well-described in product data, and supported by reputable manufacturers and representatives. Hollow metal doors and frames are a good example. Most manufacturers produce them according to one or both of two sets of common industry standards, published by the Steel Door Institute (SDI) and the National Association of Architectural Metal Manufacturers (NAAMM). Unfortunately, not all types of building products can be specified by use of similar standards.
Before you start that e-mail telling me how difficult it is to specify hollow metal doors,
14 April 2010
Moving on
We just went through another round of bylaws amendments, and unless we decide to throw everything out and start over, we should be about done. The reason behind many of the amendments goes back to the governance initiative recommended by the Board and approved by the members just a couple of years ago. As you may recall, one of the biggest changes was to reduce the board of directors from twenty-nine members to eighteen. We’re well on the way now; we soon will be down to twenty board members.
The intent of the governance amendment was to create a smaller board, one that would be more nimble, more efficient, and more forward thinking. With that in mind, let us consider two Board activities: creation of a new committee to oversee the way members use their dues, and expanding CSI’s visibility and influence through increased participation of corporations.
The intent of the governance amendment was to create a smaller board, one that would be more nimble, more efficient, and more forward thinking. With that in mind, let us consider two Board activities: creation of a new committee to oversee the way members use their dues, and expanding CSI’s visibility and influence through increased participation of corporations.
01 April 2010
Scar on EnergyStar
EnergyStar-approved gasoline-powered alarm clock? Heater with feather duster and flypaper?
When the interest in green design took hold, I observed that an organization with a lot of money would be required to establish green standards. The typical design firm doesn't have the capacity to investigate and evaluate the source, processing, transportation, installation, performance, content, recyclability, and so on for even a single product. It is even more difficult than that, as the same analysis is required for each thing that affects or is affected by the product being studied. Throw in the effects of government subsidies, market preferences, conflicting claims from competing sources, and more, and trying to determine how green even a simple assembly is becomes virtually impossible.
And even if each firm were capable of doing all that, why should all that work be duplicated? Each firm doesn't determine the required characteristics of structural steel or foam insulation, then test the material to make sure it's what it should be; instead, we let someone else - ASTM, for example - set standards and then require compliance with those standards. Why not do the same for green products? Use of industry-wide standards helps achieve consistency and reliability, and makes it easier to specify, manufacture, and install most construction products.
The organization with the most money is, of course, the Federal government. I said it then, and I’ll stay with what I said - this is a job the government is in the best position to take on. Unfortunately, these are the same people who wrote our tax code, see football blackouts and deregulation of cable TV as more important than infrastructure, and try to justify building a $400 million bridge to serve an island with fifty residents.
So we shouldn’t be surprised when a government-backed green standards organization exhibits the typical civil serpent’s approach to reviewing submittals. The March 25 online New York Times carried an article titled “Audit Finds Vulnerability of EnergyStar Program” in which it is reported that EnergyStar-approved products included a space heater with a feather duster and flypaper strips, and a gasoline powered alarm clock.
read the article; read the GAO report
When the interest in green design took hold, I observed that an organization with a lot of money would be required to establish green standards. The typical design firm doesn't have the capacity to investigate and evaluate the source, processing, transportation, installation, performance, content, recyclability, and so on for even a single product. It is even more difficult than that, as the same analysis is required for each thing that affects or is affected by the product being studied. Throw in the effects of government subsidies, market preferences, conflicting claims from competing sources, and more, and trying to determine how green even a simple assembly is becomes virtually impossible.
And even if each firm were capable of doing all that, why should all that work be duplicated? Each firm doesn't determine the required characteristics of structural steel or foam insulation, then test the material to make sure it's what it should be; instead, we let someone else - ASTM, for example - set standards and then require compliance with those standards. Why not do the same for green products? Use of industry-wide standards helps achieve consistency and reliability, and makes it easier to specify, manufacture, and install most construction products.
The organization with the most money is, of course, the Federal government. I said it then, and I’ll stay with what I said - this is a job the government is in the best position to take on. Unfortunately, these are the same people who wrote our tax code, see football blackouts and deregulation of cable TV as more important than infrastructure, and try to justify building a $400 million bridge to serve an island with fifty residents.
So we shouldn’t be surprised when a government-backed green standards organization exhibits the typical civil serpent’s approach to reviewing submittals. The March 25 online New York Times carried an article titled “Audit Finds Vulnerability of EnergyStar Program” in which it is reported that EnergyStar-approved products included a space heater with a feather duster and flypaper strips, and a gasoline powered alarm clock.
read the article; read the GAO report
03 March 2010
A Request to Industry Professionals
Among CSI's 13,000 members are the top experts on construction products - the people who make and install them. Despite this wealth of knowledge, one of the most common complaints of newsletter editors and website managers is, "I don't have any articles!" To solve this problem, all we need do is turn to our industry professionals. Who better than the manufacturer of a product knows its characteristics or how it performs? And who knows more than a qualified installer about conditions required for a successful installation?
When manufacturers and installers see specifications or drawings that are unclear, incomplete, or simply wrong, they are presented with a great opportunity to help design professionals do better. Does the indicated assembly require another component? Is that manufacturer out of business? Are the specified accessories incompatible? Is the detail impossible to construct? Have the referenced standards been updated?
Many of these problems and conflicts can be discussed in short articles, then submitted for publication in chapter newsletters or websites where they can be seen by design professionals. To ignore a recurring problem - or just complain about it - doesn't do anyone any good. So the next time you see a problem, especially if you've seen it more than once, take a few minutes to explain what is wrong and how it should be done, and send it to your chapter editor. Specifiers will love you!
When manufacturers and installers see specifications or drawings that are unclear, incomplete, or simply wrong, they are presented with a great opportunity to help design professionals do better. Does the indicated assembly require another component? Is that manufacturer out of business? Are the specified accessories incompatible? Is the detail impossible to construct? Have the referenced standards been updated?
Many of these problems and conflicts can be discussed in short articles, then submitted for publication in chapter newsletters or websites where they can be seen by design professionals. To ignore a recurring problem - or just complain about it - doesn't do anyone any good. So the next time you see a problem, especially if you've seen it more than once, take a few minutes to explain what is wrong and how it should be done, and send it to your chapter editor. Specifiers will love you!
21 February 2010
Finish Mock-Ups
I recently received an e-mail from one of my favorite architects, asking for help with an unsatisfactory drywall installation. Using the Gypsum Association's GA-216 - Application and Finishing of Gypsum Panel Products as a reference standard, he had specified a Level 5 finish, yet he still was having a difference of opinion with the installer.
I was a bit surprised this was an issue. We specify Level 4 for almost everything and have had few problems; it’s hard to imagine not getting a good Level 5 finish when specified. The exceptions, as you might expect, have been walls at an angle to large windows, or walls with down lighting, and the higher the sheen of the paint, the worse the problem.
I was a bit surprised this was an issue. We specify Level 4 for almost everything and have had few problems; it’s hard to imagine not getting a good Level 5 finish when specified. The exceptions, as you might expect, have been walls at an angle to large windows, or walls with down lighting, and the higher the sheen of the paint, the worse the problem.
02 February 2010
History Lesson
In February 2007, John C. Anderson, FCSI, Distinguished Member of the Institute, charter member and first president of the Minneapolis-St. Paul Chapter, and fourteenth president of the Institute, passed away. A visionary, John foresaw the value of computers for bringing automation and consistency to specifications, and was a founder of the Construction Sciences Research Foundation (CSRF). John continued to serve CSI and the construction industry in many ways long after his term as president; in addition to serving as a CSRF director, he also was active in AIA, a member of AIA's Professional Development and Intern Development Program Committees, and a member of the National Panel of the American Arbitration Association.
In 1986, the Minneapolis-St. Paul Chapter named its highest award in his honor - the John C. Anderson Award of Excellence. Because he was a member of the Minneapolis-St. Paul Chapter and an important influence in my life, I prepared a tribute to honor his memory at our chapter awards banquet. While working on that project, I confirmed something I had previously suspected - for an organization that is heavily involved in documentation, we have done a poor job of keeping our own records.
In 1986, the Minneapolis-St. Paul Chapter named its highest award in his honor - the John C. Anderson Award of Excellence. Because he was a member of the Minneapolis-St. Paul Chapter and an important influence in my life, I prepared a tribute to honor his memory at our chapter awards banquet. While working on that project, I confirmed something I had previously suspected - for an organization that is heavily involved in documentation, we have done a poor job of keeping our own records.
12 January 2010
On the other hand...
After CSI’s October 2009 Board Flash, I wrote “A rose is a rose…”, in which I questioned the need for a change of member classification based on the vague explanation that was offered - “The Board believes the condensing of member classifications better reflects CSI's core value of building teamwork among construction professionals.” I also asked for more justification.
In response, I was accused of “old thinking.” Interesting, given that all I had done was review a little history, show that - with the exception of choosing leaders - there is no difference between members, and point out the need to again change chapter bylaws if the amendment is approved. I hoped we might have a little open discussion, and that advocates of change would provide sound reasons for the proposed change.
Remembering how much fun I had I college, taking any side of an argument just for fun, I decided to give the proponents of change a little help, and look at reasons for making the change from three member types to one. There is a good reason for making the change, and we’ll get to it. But first, I’ll comment on the claims that were posted. Sorry, but you’ll have to put up with more of my old thinking.
In response, I was accused of “old thinking.” Interesting, given that all I had done was review a little history, show that - with the exception of choosing leaders - there is no difference between members, and point out the need to again change chapter bylaws if the amendment is approved. I hoped we might have a little open discussion, and that advocates of change would provide sound reasons for the proposed change.
Remembering how much fun I had I college, taking any side of an argument just for fun, I decided to give the proponents of change a little help, and look at reasons for making the change from three member types to one. There is a good reason for making the change, and we’ll get to it. But first, I’ll comment on the claims that were posted. Sorry, but you’ll have to put up with more of my old thinking.
Subscribe to:
Posts (Atom)